Jurnal Ilmiah Teknik Sipil Vol. 16, No. 2, Juli 2012 212 PENGUJIAN KEKUATAN PENGHUBUNG GESER YANG TERBUAT DARI BAJA TULANGAN BERBENTUK “U TERBALIK” Ida Ayu Made Budiwati 1 , IB. Dharma Giri 1 , dan Ketut Candra Priska Wedana 2 1 Dosen Jurusan Teknik Sipil, Fakultas Teknik Universitas Udayana, Denpasar 2Jurusan Teknik Sipil, Fakultas Teknik Universitas Udayana, Denpasar Abstrak: Penelitian ini menganalisis kekuatan penghubung geser “U terbalik” berdasarkan hubungan slip dan beban dengan mutu beton berbeda dan luas penampang serta sudut kemiringan yang digunakan sama. Penghubung geser merupakan potongan baja tulangan polos diameter Ø 10 mm panjang 400 mm berbentuk huruf “U terbalik” yang dimiringkan sebesar 450 terhadap sayap balok baja profil IWF (250x125x6x9) mm. Pengujian dilakukan terhadap 6 spesimen komposit dengan mutu beton yang berbeda yakni sebesar 21.79 MPa (benda uji C 20) dan 30,84 Mpa (benda uji C 25) masing-masing terdiri atas 3 spesimen mutu beton. Pengujian kekuatan penghubung geser dengan metode Push Out Test berdasarkan standar Australia (AS 2327 Part 1, 1980). Hasil tes menunjukkan bahwa meningkatnya mutu beton menyebabkan menurunnya nilai slip yang berarti peningkatan kapasitas beban yang dapat ditahan oleh benda uji. Pada saat diberikan beban sebesar 72,5 kN terhadap masing-masing penghubung geser pada benda uji, slip yang dihasilkan oleh C 20 dan C25 berturut-turut sebesar 2,433 mm dan 1,060 mm. Pada kenaikan mutu beton sebesar 41,53%, maka penurunan slip C 25 terhadap C 20 adalah sebesar 56,43%. Pada spesimen C 20 dan C 25 beban ultimit belum dicapai dengan beban 72,5 kN sehingga beban yang masih mampu diterima dalam kondisi elastis hingga sebesar 72,5 kN untuk setiap penghubung geser. Kata kunci: Kuat Tekan, Mutu Beton, Penghubung Geser, Push Out Test, Slip. STRENGTH TESTING OF SHEAR CONNECTOR MADE OF REINFORCING STEEL SHAPED “INVERTED U” Abstract: This research aims to determine the shear connector strength indicated by slip and loading value in which the compressive strength of concrete is varied while the area of cross-section and length and angle of shear connector used are constant. Shear connectors are made of reinforcing steel of 10 mm diameter. On each flange of IWF section a shear connector with a length of 400 mm is mounted. In this study, shear connectors used are made of reinforcing steel shaped "inverted U" and tilted toward of 450 to the flange steel I section (250x125x6x9) mm. Shear connector strength testing is carried out using six composite specimens, with two differents concrete compressive strength that of 21.79 Mpa (spesimen C 20) and 30,84 MPa (spesimen C 25) respectively. Each compressive strength of concrete consists of three specimens. Testing specimen was conducted using push out test method refers to the Australian standard (AS 2327 Part 1, 1980). The result of the test indicating the increase of the compressive strength of concrete can lead to declining value of the slip. Decrease slip value reflects increase load capacity that can be retained by the specimen. When the load was 72.5 kN on each shear connector of the specimen, the slip occured by the C 20 and C 25 were 2.433 mm and 1.060 mm respectively. Therefore, the increase in concrete quality by 41.53%, the value of slip reduced by 56,43%. The specimen of C 20 and C 25 have not been reached the ultimate load so it is believed that each shear connector still be able to recieve the load in elastic conditions more than 72.5 kN. Keywords: Compressive Strength, Concrete trength, Push Out Test, Shear Connector, Slip.