Spektrum Augenheilkd (2007) 21/1: 13–16
DOI 10.1007/s00717-006-0172-y
© Springer-Verlag 2007
Printed in Austria
Spektrum
der Augenheilkunde
Dreidimensionale Rekonstruktion von Schichtbildaufnahmen der Netzhaut
C. Glittenberg
1
, B. Považay
2
, B. Hermann
2
, F. Zeiler
1
, C. Falkner
1
, W. Drexler
2
und S. Binder
1
1
Ludwig-Boltzmann-Institut für Retinologie und Biomikroskopische Laser Chirurgie, Augenabteilung, Rudolf-Stiftung, Wien, Österreich
2
Biomedical Imaging Group, Department of Optometry & Vision Sciences, Cardiff University, Wales, UK
Zusammenfassung. Zielsetzung: Die Entwicklung eines
neuen Darstellungssystems für die dreidimensionale Visua-
lisierung von Schichtbildaufnahmen in der Augenheilkunde.
Im Speziellen, ein System das B-Mode-Scan-Datensätze von
einer ultrahochauflösenden optischen Kohärenztomographie-
untersuchung als plastische dreidimensionale Objekte dar-
stellen kann.
Methode: Im Rendering- und Raytracing-Programm Ci-
nema 4D XL 9.102 Studio Bundle (Maxon Computer GmbH,
Friedrichsburg, Deutschland) wurden mehrere „Subroutinen“
programmiert die Schichtbildaufnahmen zu dreidimensio-
nalen Darstellungen verarbeiten können. Es wurden von Pati-
enten mit verschiedenen Netzhauterkrankungen ultrahochauf-
lösende optische Kohärenztomographien aufgenommen, und
mit den programmierten „Subroutinen“ zu dreidimensionalen
Objekten weiterverarbeitet. Alle ultrahochauflösenden op-
tischen Kohärenztomographie-Untersuchungen wurden mit
einem Ultrabreitband (160 nm) Titan:Saphire basierten Fem-
tosecunden-Laser-System (INTEGRAL, Femtolasers Pro-
ductions GmbH, Vienna, Austria) mit einer axialen Auflö-
sung von 3 μm durchgeführt.
Resultate: Es wurde ein neues dreidimensionales Dar-
stellungssystem für Schichtbildaufnahmen in der Augenheil-
kunde entwickelt das eine sehr plastische Darstellung von
physiologischen und pathologischen Strukturen in der Netz-
haut erlaubt. Das System zeichnet sich zusätzlich durch eine
hohe Interaktivität sowie durch eine große Anpassungsfähig-
keit aus.
Schlussfolgerung: Das neue Darstellungssystem erlaubt
die Visualisierung von physiologischen und pathologischen
Strukturen der Netzhaut in einer Art und Weise, die uns neue
Einsicht über deren Morphologien und Entwicklungen geben
wird.
Schlüsselwörter: UHR-OCT, Netzhaut, 3D.
Three dimensional reconstruction of tomographic
images of the retina
Summary. Purpose: The development of a new display sys-
tem for the three-dimensional visualization of tomographic
images in ophthalmology. Specifically, a system that can use
stacks of B-mode scans from an ultrahigh resolution optical
tomography examination to vividly display retinal specimens
as three-dimensional objects.
Methods: Several subroutines were programmed in the
rendering and raytracing program Cinema 4D XL 9.102
Studio Bundle (Maxon Computer Inc., Friedrichsburg, Ger-
many), which could process stacks of tomographic scans into
three-dimensional objects. Ultrahigh resolution optical coher-
ence tomography examinations were performed on patients
with various retinal pathologies and post processed with the
subroutines that had been designed. All ultrahigh resolution
optical coherence tomographies were performed with a tita-
nium: sapphire based ultra broad bandwidth (160nm) femto-
second laser system (INTEGRAL, Femtolasers Productions
GmbH. Vienna Austria) with an axial resolution of 3μm.
Results: A new three dimensional display system for to-
mographic images in ophthalmology was developed, which
allows a highly vivid display of physiological and pathologi-
cal structures of the retina. The system also distinguishes it-
self through its high interactivity and adaptability.
Conclusion: This new display system allows the visual-
ization of physiological and pathological structures of the
retina in a new way, which will give us new insight into their
morphology and development.
Key words: UHR-OCT, retina, 3D.
Hintergrund
Um ein echtes Verständnis der morphologischen und patho-
logischen Zusammenhänge eines Organs zu erlangen ist es
notwendig dieses in seiner ganzen räumlichen Struktur zu
begreifen. Um eine solche räumliche Struktur darstellen
zu können ist es notwendig eine Reihe von Schichtbildauf-
nahmen zu erzeugen und anhand dieser eine dreidimensio-
nale Rekonstruktion des Organs zu erstellen. In Disziplinen
außerhalb der Augenheilkunde ist die Technologie, derartige
Rekonstruktionen zu erzeugen, schon weit vorangeschritten.
Das Osirix
®
-System [1] ist eines der besten Programme um
anhand von Computertomographie-Datensätzen dreidimensi-
onale Darstellungen von Organen und Differenzierung von
Gewebeschichten zu erzeugen. Dieses System ist auch in der
Lage eine eindrucksvolle Oberflächenerkennung von ver-
schiedenen Gewebearten anhand von Schichtbildaufnahmen
zu erstellen.
Die Voxelgröße der Schichtbilddatensätze beträgt bei der
hochauflösenden Computertomographie 0,117 mm × 0,177