Please cite this article in press as: Matias CN, et al. Total body water and water compartments assessment in athletes:
Validity of multi-frequency bioelectrical impedance. Sci sports (2018), https://doi.org/10.1016/j.scispo.2018.11.007
ARTICLE IN PRESS
+Model
SCISPO-3287; No. of Pages 7
Science & Sports (2018) xxx, xxx—xxx
Disponible en ligne sur
ScienceDirect
www.sciencedirect.com
ORIGINAL ARTICLE
Total body water and water compartments
assessment in athletes: Validity of
multi-frequency bioelectrical impedance
Évaluation de l’eau corporelle totale et des compartiments
d’eau chez les athlètes : validité de l’impédance
bioélectrique multifréquence
C.N. Matias
a,b,*
, F.A. Noujeimi
c
, L.B. Sardinha
a
,
V.H. Teixeira
c,d
, A.M. Silva
a
a
Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade Lisboa, Estrada da
Costa, 1499-002 Cruz Quebrada, Portugal
b
Physiology and Biochemistry of Exercise Laboratory, CIPER, Faculdade Motricidade Humana, Universidade
Lisboa, Estrada da Costa, 1499-002 Cruz Quebrada, Portugal
c
Centro de Investigac ¸ão em Atividade Física (CIAFEL), Saúde e Lazer, Faculdade de Desporto, Universidade
do Porto, 91, rua Dr. Plácido Costa, 4200-450 Porto, Portugal
d
Faculdade de Ciências da Nutric ¸ão e Alimentac ¸ão, Universidade do Porto, rua Dr. Roberto Frias, 4200-465
Porto, Portugal
Received 5 June 2018; accepted 27 November 2018
KEYWORDS
Athletes;
Body water;
Water compartments;
Multi-frequency
bioelectrical
impedance;
Dilution techniques
Summary Bioelectrical impedance provides an affordable assessment of the body’s water
compartments: total body water (TBW), extracellular (ECW) and intracellular water (ICW).
However, little is known of its validity in athletes. We aim to validate TBW, ECW, and ICW
obtained by multi-frequency bioelectrical impedance (MFBIA), using dilution techniques as
reference (REF) in athletes. Thirty-six elite athletes (17males and 19females) with a mean
age of 18.5 ± 4.1 years were evaluated. TBW, ECW, and ICW were assessed by MFBIA (Tanita
MC-180MA) and dilution techniques. TBW
REF
and ECW
REF
were obtained by deuterium and bro-
mide dilution techniques, respectively, while ICW
REF
was calculated as their difference. MFBIA
underestimated ECW (∼1.3 kg) and overestimated TBW (∼1 kg) and ICW (∼3.5 kg), in relation to
criterion. MFBIA explained 96%, 81%, and 83% of the total variability of results obtained from the
reference for TBW, ECW, and ICW respectively. Standard error of the estimates ranged between
∗
Corresponding author. Faculdade de Motricidade Humana, Universidade de Lisboa, CIPER, Estrada da Costa, 1499-002 Cruz Quebrada,
Portugal.
E-mail address: cmatias@fmh.ulisboa.pt (C.N. Matias).
https://doi.org/10.1016/j.scispo.2018.11.007
0765-1597/© 2018 Elsevier Masson SAS. All rights reserved.