Correction
Correction: Antonelli, A., et al. Can Bone Compaction Improve
Primary Implant Stability? An In Vitro Comparative Study with
Osseodensification Technique. Applied Sciences 2020, 10, 8623
Alessandro Antonelli
1,
* , Francesco Bennardo
1
, Ylenia Brancaccio
1
, Selene Barone
1
, Felice Femiano
2
,
Ludovica Nucci
2
, Giuseppe Minervini
2
, Leonzio Fortunato
1
, Ferdinando Attanasio
1
and Amerigo Giudice
1
Citation: Antonelli, A.; Bennardo, F.;
Brancaccio, Y.; Barone, S.; Femiano, F.;
Nucci, L.; Minervini, G.; Fortunato, L.;
Attanasio, F.; Giudice, A. Correction:
Antonelli, A., et al. Can Bone
Compaction Improve Primary
Implant Stability? An In Vitro
Comparative Study with
Osseodensification Technique.
Applied Sciences 2020, 10, 8623. Appl.
Sci. 2021, 11, 3427. https://doi.org/
10.3390/app11083427
Received: 15 March 2021
Accepted: 26 March 2021
Published: 12 April 2021
Publisher’s Note: MDPI stays neutral
with regard to jurisdictional claims in
published maps and institutional affil-
iations.
Copyright: © 2021 by the authors.
Licensee MDPI, Basel, Switzerland.
This article is an open access article
distributed under the terms and
conditions of the Creative Commons
Attribution (CC BY) license (https://
creativecommons.org/licenses/by/
4.0/).
1
Department of Health Sciences, School of Dentistry, Magna Græcia University of Catanzaro,
88100 Catanzaro, Italy; fbennardo92@gmail.com (F.B.); ybrancaccio@gmail.com (Y.B.);
barone.selene19@gmail.com (S.B.); leo@unicz.it (L.F.); ferdinando.attanasio@gmail.com (F.A.);
a.giudice@unicz.it (A.G.)
2
Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania,
Luigi Vanvitelli, 80138 Naples, Italy; femiano@libero.it (F.F.); ludovica.nucci@unicampania.it (L.N.);
minervinigiuseppe@hotmail.it (G.M.)
* Correspondence: antonellicz@gmail.com; Tel.: +961-712-446
The author wishes to make the following corrections to this paper [1].
1. Change in Figure
In the original article, there was a mistake in Figure 1 as published. During the check
of the manuscript the authors observed that an incorrect picture was uploaded during the
submission phases. The corrected Figure 1 appears below. The authors apologize for any
inconvenience caused and state that the scientific conclusions are unaffected. The original
article has been updated.
2. Text Correction
The authors provide some additional necessary information about the limitations of
the study and the conclusion section.
“Moreover, the use of manual bone spreaders preserves a significant amount of
bone, exploiting the elastic feature of the soft bone, positively improving the implant
primary stability. Nevertheless, several in vivo studies are required to analyze any possible
difference between the surgical techniques (BC and OD) performed in this study, in terms
of histological healing and long- term clinical data with success rates”.
Many sentences in the Discussion section have been modified in part to making sure
that the readers could better understand the manuscript’s aim:
“According to the literature, there is no clear correlation between PIT and ISQ. Furher-
more, ISQ is not an effective one-time measurement parameter, however it is designed to
be a time-related parameter [31]”.
Appl. Sci. 2021, 11, 3427. https://doi.org/10.3390/app11083427 https://www.mdpi.com/journal/applsci