Jurnal Teras Kesehatan |ISSN (p): 2622-2396 | ISSN (e): 2622-3805 | Vol. 7 | No. 1 | [ Januari] [2024] DOI: https://doi.org/10.38215/jtkes.v7i1.100 Jurnal Teras Kesehatan – 1 PENGUKURAN DOSIS RADIASI YANG DITERIMA ORGAN TIROID PADA PEMERIKSAAN SHOULDER JOINT Cicillia Artitin 1* , Nada Regina 2 , Prodi D III Radiologi, Fakultas Vokasi, Universitas Baiturrahmah, Padang cicillia.artitin.ca@gmail.com ABSTRAK Salah satu pemeriksaan yang ada di instalasi radiologi adalah Shoulder Joint, dimana pemeriksaan tersebut dekat dengan salah satu organ sensitif yaitu tiroid. Jika tiroid menyerap terlalu banyak radiasi akan menumbulkan efek yaitu Kanker tiroid dan Tumor tiroid. Penelitian ini bertujuan untuk mengetahui berapa besar dosis radiasi yang diterima tiroid apakah dosis yang diterima melebihi nilai batas dosis yang sudah ditetapkan. Jenis Penelitian studi kuantitatif, dilakukan di instansi radiologi RSI Ibnu Sina Padang pada tanggal 05 Agustus 2022 metodenya bersifat studi eksperimental, menggunakan 10 sampel dengan alat ukur raysafe. Kemudian data diolah menggunakan rumus dosis efektif dan ditampilkan dalam bentuk tabel. Hasil yang diperoleh berupa dosis serap kemudian dijadikan kedalam dosis ekuivalen dengan cara mengalihkan dosis serap dengan faktor bobot radiasi. Selanjutnya dosis ekuivalen dikalikan dengan faktor bobot jaringan organ tiroid dan didapatkan hasil dosis efektif. Didapatkan hasil yaitu nilai dosis efektif yang diterima organ tiroid pada pemeriksaan Shoulder Joint berkisar antara 0,000103 mSv – 0,00033 mSv. Dosis yang diterima organ tiroid pada pemeriksaan Shoulder Joint masih dalam batas aman karena tidak melebihi nilai batas dosis yang telah ditetapkan dalam Perka BAPETEN yaitu 15 mSv dalam satu tahun. Kata Kunci : Dosis Radiasi, Organ Tiroid, Raysafe ABSTRACT One of the examinations in the radiology installation is the Shoulder Joint, where a sensitive organ close to the examination is the thyroid. If the thyroid organ absorbs too much radiation, it causes the effects of thyroid cancer and thyroid tumor. This research aims to determine how the dose received by the thyroid and whether the dose received exceeds the prescribed dose limit value. The type of research is a quantitative done at the installation radiology of Ibnu Sina Islamic Hospital Padang on 5 August 2021. The method is an experimental study, using ten samples with raysafe measuring instruments. Then the data is processed using the effective dose formula and displayed in tabular form. The results obtained in the form of absorbed dose are then converted into equivalent doses by switching the absorbed dose to the radiation weight factor. Furthermore, the equivalent dose is multiplied by the weight factor of the thyroid organ tissue and the results of the effective dose are obtained. The results were obtained, namely the value of the effective dose received by the thyroid organ on the projection Shoulder Joint examination ranging from 0,000103 mSv – 0,00033 mSv. The dose received by the thyroid organ on the Shoulder Joint examination is still within safe limits because it does not exceed the dose limit value that has been set in the BAPETEN Perka, which is 15 mSv in one year. Keywords : Radiation Dose, Thyroid Organ, Raysafe. PENDAHULUAN Radiasi dapat diartikan sebagai energi yang dipancarkan dalam bentuk partikel atau gelombang yang memiliki daya tembus, penyerapan, ionisasi dan efek biologi. Efek radiasi terbagi menjadi dua yaitu efek deterministik dan efek stokastik. Efek deterministik muncul seketika atau beberapa minggu setelah terkena radiasi yang ditandai dengan keluhan, baik umum maupun lokal yang sulit dibedakan dengan penyakit lainnya, dimana keluhan umum seperti nafsu makan