Behavior and mechanisms of steel plate shear walls with coupling
Daniel J. Borello, Larry A. Fahnestock ⁎
Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA
abstract article info
Article history:
Received 11 November 2011
Accepted 21 December 2011
Available online 28 March 2012
Keywords:
Steel framed buildings
Shear walls
Coupled walls
Earthquake resistant structures
Plastic analysis
Nonlinear static analysis
The Steel Plate Shear Wall with Coupling (SPSW-WC) system consists of a pair of planar SPSWs linked to-
gether with coupling beams at the floor levels. The degree of coupling, which represents the level of interac-
tion between the two piers, and the plastic strength for a SPSW-WC are important parameters in
understanding behavior and developing designs for the system. This paper examines these two parameters
using plastic analysis and numerical simulations of single story and multi-story SPSW-WC configurations.
The focus is on desirable uniform-yielding mechanisms, but soft-story mechanisms are also briefly discussed,
and analytical closed-form expressions are developed for ultimate strength and degree of coupling. Thirty-
two SPSW-WC structures are designed with emphasis on varying the following parameters: height of the
structure (number of stories), coupled length and coupling beam properties. These structures are studied
with numerical models using monotonic nonlinear static analysis. Good agreement is observed between
the numerical simulations and the analytical predictions for the ultimate strength and degree of coupling.
The degree of coupling is shown to have a significant impact on structural weight, particularly for the taller
structures studied, and the optimal degree of coupling to maximize material efficiency is found to be in the
range of 0.4 to 0.6.
© 2011 Elsevier Ltd. All rights reserved.
1. Introduction
The Steel Plate Shear Wall (SPSW) system is used in North America
and Japan as a lateral force resisting system for high seismic regions. A
SPSW consists of a steel frame with slender web plates connected to
the surrounding beams and columns, referred to as Horizontal Bound-
ary Elements (HBE) and Vertical Boundary Elements (VBE), respective-
ly. Due to architectural requirements, the lateral force resisting system
is typically placed around the perimeter of the building core. To accom-
modate openings in the core, it may be natural to place two SPSWs ad-
jacently. Additionally, the American Institute of Steel Construction
Seismic Provisions traditionally limited the panel length to height ratio
to 2.5 [1], often encouraging the segmentation of a single bay into two
adjacent SPSWs. Therefore, it is a logical extension of the SPSW system
to link two planar SPSWs at the floor levels with Coupling Beams (CB) to
form a Steel Plate Shear Wall with Coupling (SPSW-WC) as shown in
Fig. 1.
In the United States, SPSW web plates are typically slender and
unstiffened and the boundary elements are rigidly connected [1].
Thorburn et al. [2] first recognized the post-buckling strength of
SPSW web plates. Similar to tension-field action in plate girders [3],
a web plate buckles under shear force but provides significant post-
buckling resistance by developing a diagonal tension field. However,
unlike plate girders, the boundary elements are proportioned to an-
chor the diagonal tension field so that complete web plate tension
yielding can develop. The angle of the tension field α, measured
from the vertical, was derived by Timler and Kulak [4] based on a
least work formulation:
tan
4
α ¼
1 þ
tL
2A
c
1 þ th
1
A
b
þ
h
3
360I
c
L
ð1Þ
where t is the web plate thickness, h is the distance between HBE cen-
terlines, L is the distance between VBE centerlines, A
b
is the average
cross-sectional area of the HBEs, A
c
is the average cross-sectional
area of the VBEs, and I
c
is the average moment of inertia of the VBEs.
The strip model, a simplified analytical tool, was developed based
on Eq. (1) to analyze the SPSW system [2,4]. The diagonal tension
field is represented by tension-only truss elements inclined at an
angle α with a cross-sectional area equal to the product of their trib-
utary width and the web plate thickness as shown in Fig. 2. The strip
model has been compared extensively with experimental data and
has been demonstrate to accurately capture the global system behav-
ior [4–6].
In a planar SPSW system the overturning moment due to lateral
loads is resisted primarily through two mechanisms (Fig. 2): (1) the
moment within the individual VBEs (M
VBE
) and (2) the couple formed
by the axial force in the VBEs induced by the web plates and HBEs
(M
PIER
). The SPSW-WC system introduces an additional mechanism
Journal of Constructional Steel Research 74 (2012) 8–16
⁎ Corresponding author. Tel.: + 1 217 265 0211; fax: + 1 217 265 8040.
E-mail address: fhnstck@illinois.edu (L.A. Fahnestock).
0143-974X/$ – see front matter © 2011 Elsevier Ltd. All rights reserved.
doi:10.1016/j.jcsr.2011.12.009
Contents lists available at SciVerse ScienceDirect
Journal of Constructional Steel Research