CERN-ATS-2010-081 30/05/2010 IMPACT OF THE EXPERIMENT SOLENOID ON THE CLIC LUMINOSITY The main detector solenoid and associated magnets can have an important impact on the CLIC luminosity. These effects are discussed for different solenoid designs. In particular, the luminosity loss due to incoherent synchrotron radiation in the experiment solenoid and QD0 overlap is evaluated. The impact of the AntiDiD (Anti-Detector integrated Dipole) on luminosity and of compensated techniques on beam optic distortion are also discussed EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN - ACCELERATORS AND TECHNOLOGY SECTOR Abstract B. Dalena, D. Schulte, R. Tomas Garcia CERN-ATS-2010-081 Presented at : 1 rst International Particle Accelerator Conference (IPAC 2010) May 23-28, 2010, Kyoto, Japan Geneva, Switzerland May 2010