ABSTRACT: The feasibility of applying methods developed by
Safety Associates, Inc., to monitor oil degradation products, in-
cluding malondialdehydes (AldeSafe
TM
), FFA (FASafe
TM
), and
peroxides (PeroxySafe
TM
), in fresh and heat-abused deep-fat fry-
ing oil was evaluated. Based on performance qualification stud-
ies, the AldeSafe method was the most suitable SafTest
TM
assay
for monitoring the quality of frying oil because of its high accu-
racy, precision, linearity, and reproducibility, and low detec-
tion/quantitation limits. A strong correlation (r = 0.924) between
the AldeSafe method and its counterpart, AOCS Official Method
Cd 19-90, also supported the suitability of the SafTest method for
monitoring oil quality. Moreover, the FASafe method had a mod-
erately strong relationship with AOCS Official Method Ca 5a-40
(r = 0.761). Our studies suggest that this test can be applied for
monitoring frying oil; however, certain method performance lim-
itations must be considered for routine analysis purposes. In con-
trast, the PeroxySafe method probably should not be used to mon-
itor heat-abused oil without further development because of high
variability, low accuracy, and low correlation (r = 0.062) with the
AOCS Official Method Cd 8-53 assay.
Paper no. J11254 in JAOCS 83, 15–20 (January 2006).
KEY WORDS:Assay correlation, deep frying, free fatty acids,
method qualification, malondialdehyde, oil degradation prod-
ucts, oil quality indicators, peroxides.
Controlling deep-fat frying processes is crucial in the food in-
dustry, as oil degradation products can compromise the qual-
ity of the oil over time and may be harmful to human health
(1–6). Peroxides and malondialdehyde (MDA) are applicable
indicators of oil quality, as these oxidation by-products are
produced from several frying parameters, i.e., light, elevated
temperatures, oxygen, water in the food, and the like (7,8).
FFA are another oil quality indicator because these molecules
are cleaved from TAG when steam reacts with oil at the ele-
vated temperatures typically used in a deep-fat frying process
(2). Although AOCS official methods are available for moni-
toring the cited indicators of degraded oil, several disadvan-
tages exist in their application (9–11). For example, haz-
ardous chemicals are needed for some of the tests; therefore,
appropriate safety equipment and additional waste disposal
must be considered. Bias and manual errors can also occur
when performing the titration-based methods for FFA and
peroxides. To complete the MDA-AOCS method, 2-thiobar
bituric acid (TBA) is combined with the test sample and a
pigment is formed in the presence of MDA, which can the
be monitored at a wavelength of 530 nm (8,12). However,
TBA reacts with other molecules, including ketones, ketos
teroids, acids, esters, sugars, imides and amides, amino a
oxidized proteins, pyridines, and pyrimidines (13). In addi
tion, solution and/or standard preparation requirements in
crease the time required to complete the AOCS assays.
Methods developed by Safety Associates, Inc., (Tempe,
AZ) under the brand name of SafTest
TM
may be promising al-
ternatives to the official AOCS assays for monitoring fryin
oil quality because peroxides, MDA, and FFA can easily be
detected (14). Samples are prepared for this system by so
bilizing the food matrix with a proprietary preparation sol
tion, separating the quality indicator from other food com
nents when necessary, and reacting the ensuing extract w
proprietary reagents. The quality indicators are detected
an optical reader programmed to quantitate the molecule
interest against a previously established calibration curve
the test reagents, calibration standards, controls, membra
packs, and so on are available in kits specific to the qualit
indicator of interest. As a result, the SafTest system gener
less waste, does not require timely standardized solut
preparations, and is capable of higher sample analyses th
the AOCS methods.
Despite internal studies conducted by the manufacturer
showing the successful application of the SafTest methods
various food systems, these assays have not been used ext
sively in the food industry. The purpose of these studies w
to determine the feasibility of using the SafTest system to
monitor the quality of frying oil heated for extended perio
of time. Assay qualification studies were initially performe
to evaluate the basic performance characteristics of t
SafTest assays. These methods were then compared with
official AOCS counterparts.
MATERIALS AND METHODS
Reagents and solutions. AldeSafe
TM
, FASafe
TM
, and Peroxy-
Safe
TM
kits were purchased from Safety Associates, Inc. Ea
kit contained the following items: preparation solution, an
lyte reaction reagents, positive controls (low, high, an
medium), and 3 to 5 standards of known concentrations. T
reagents purchased to complete the AOCS test consisted o
acetic acid, 1 N sodium hydroxide, glacial acetic acid (J.T.
Copyright © 2006 by AOCS Press 15 JAOCS, Vol. 83, no. 1 (2006)
*To whom correspondence should be addressed at Department of Food Sci-
ence and Technology, 143 Filley Hall, University of Nebraska, Lincoln, NE
68583-0919. E-mail: vlschleg@unlnotes.unl.edu
Evaluation of SafTest
TM
Methods
for Monitoring Frying Oil Quality
Swee Yee Foo, Susan Cuppett, and Vicki Schlegel*
Department of Food Science and Technology, University of Nebraska, Lincoln, Nebraska 68583-0919