Motion and Morphology of the
Thumb Metacarpophalangeal Joint
Ryo Yoshida, MD, Hugh O. House, MD, Rita M. Patterson, PhD,
Munir A. Shah, MD, Steven F. Viegas, MD, Galveston, TX
Purpose: To determine the variability in the flexion/extension motion of the thumb metacarpo-
phalangeal (MCP) joint in a normal volunteer population and to determine any correlation between
the shape of the thumb metacarpal head, gender, age, thumb interphalangeal (IP) joint range of
motion (ROM), and thumb MCP joint ROM in a population of fresh-frozen cadaver arms.
Methods: The ROM of the thumb MCP joints of 100 volunteers (200 thumbs) was measured. The
thumb MCP joints of 70 fresh-frozen cadaver arms were examined. Posteroanterior and lateral radio-
graphs were taken of 64 MCP joints. Passive flexion and extension at the MCP and IP joints were
measured with a standard goniometer starting at neutral (0°) with the metacarpal, proximal, and distal
phalanges axially aligned. The distance from the volar to the dorsal edge of the articular surface (A) and
the radius of curvature of the articular surface (r) of the metacarpal head were measured on the lateral
view. The shape of the metacarpal head was given a value using the A/r ratio. Regression analysis was
used to determine the correlation between the head shape and joint motion. The thumbs were
categorized into a round group (A/r ratio 1.7) or a flat group (A/r ratio of 1.7) to facilitate statistical
analysis.
Results: The volunteer population mean thumb MCP maximum flexion was 77° (range, 40°–126°).
Range of motion in hyperextension varied from 0° to 72°, with a mean of 35°. Total ROM was from 55°
to 176°, with a mean of 110°. In the cadaver population studied the average MCP joint ROM was 94°
(mean flexion, 70°; mean extension, 24°). The A/r ratio had a range of 1.1 to 2.2. There were 37 round
and 27 flat thumb metacarpal heads. Regression analysis showed a significant correlation between
metacarpal head shape and ROM; MCP joints with rounder metacarpal heads had greater motion.
Round and flat metacarpal heads had significantly different motion arcs averaging 106° and 77°,
respectively. Female gender was associated both with significantly greater MCP joint ROM (99°
women/87° men) and a significantly higher incidence of round metacarpal heads (66% of women/36%
of men). No significant correlation existed between specimen age, MCP, and/or IP joint ROM.
Conclusions: There is a wide range in the magnitude of the thumb MCP joint ROM and in the
normal shape (round vs flat) of the thumb metacarpal head. A rounder thumb metacarpal head has
greater thumb MCP joint ROM than a flatter thumb metacarpal head. Clinically we have found this
information helpful in predicting posttraumatic recovery of thumb MCP joint ROM and selecting
candidates for and predicting patient satisfaction with thumb MCP joint arthrodesis. (J Hand Surg
2003;28A:753–757. Copyright © 2003 by the American Society for Surgery of the Hand.)
Key words: Thumb, metacarpal joint, range of motion, morphology.
From the Division of Hand Surgery and the Division of Research, Department of Orthopaedics and Rehabilitation, The University of Texas Medical
Branch, Galveston, TX.
Received for publication February 25, 2003; accepted in revised form June 10, 2003.
No benefits in any form have been received or will be received by a commercial party related directly or indirectly to the subject of this article.
Reprint requests: Steven F. Viegas, MD, Professor and Chief, Division of Hand Surgery, Department of Orthopaedics and Rehabilitation, The
University of Texas Medical Branch, Galveston, TX 77555-0165.
Copyright © 2003 by the American Society for Surgery of the Hand
0363-5023/03/28A05-0008$30.00/0
doi:10.1053/S0363-5023(03)00303-4
The Journal of Hand Surgery 753