International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 2733
Design and Analysis of Residential Building
Shaikh Ibrahim
1
, Md Arifuzzaman
2
, Jisan Ali Mondal
3
, Md Taukir Alam
4
, Sanuwar Biswas
5
,
Sagar Biswas
6
1
Assistant professor, Civil Department, Jamia Institute of Engineering and Management Studies, Akkalkuwa,
Maharashtra, India
2,3,4,5,6
Bachelor of Engineering Student, Jamia Institute of Engineering and Management Studies, Akkalkuwa,
Maharashtra, India
---------------------------------------------------------------------***----------------------------------------------------------------------
Abstract - This Project is Generally Based on Theoretical
Design And Analysis of structural framed building. Planning,
Analysis and design of G+4 residential building structure by
using IS-Code method , manually designed and over verifies by
using software. Planning of any types of building is done by
national building code (NBC) in India, Hence the residential
building is properly planned in accordance with the national
building code of India. The reinforced concrete framed
structure consisting of G+4 with adequate facilities. All the
structure member are designed using limit state method with
reference of IS:456-2000. Different load active on the member
(beam, column) are considered according to the code
IS:875(part1,part2,part3).
Key Words: Residential Building, Staad-pro V8i
Analysis, Multi-stories Building, Design and Analysis of
Framed Building, NBC.
1. INTRODUCTION
Now a days due to overpopulation and high cost of land,
multi-storied building is more essential for metropolitan
city. Multi-storied Residential building is the perfect
solution for living of high populated area. A multi-storied
building, which posses multiple floor above the ground level,
which aim to increase the floor area of building in shortest
built up area.
Structure analysis is a subject which involves designing,
planning to built up a perfect building. Basically each project
are different with their design criteria such as incoming load,
soil properties, dynamic load, built up area etc. Here we
provided the details to complete a residential apartment
theoretically.
We firstly collected some required data to measure the soil
specific such as moisture content, bearing capacity of soil,
types of soil etc. We provided the perfect parameter in
beam, slab, column and footing with the consideration of
incoming load to avoid shear and bending collapse. In
accordance with limit state method of collapse in IS-
456:2000 we built G+4 building which deal with strength
and stability of structure under maximum design load
flexure, compression , shear and torsion .
2. LETARATURE REVIEW:
P.P. Chandurkar et. al. (2013): Study of G+9 building:
Had presented study of G+9 building having three meters
height for each storey. The whole building design had carried
out according to IS code for seismic resistant design and the
building had considered fixed at base. Structural element for
design had assumed as square or rectangular in section.
They had done modelling of building using ETAB software in
that four different models were studied with different
positioning of shear walls.
Mohit Sharma et.al. (2015): To study the dynamic
analysis of multi-storeyed Building:
He considered a G+30 storied regular reinforced concrete
framed building. Dynamic analysis of multi-storeyed
Building was carried out. These buildings have the plan area
of 25m x 45m with a storey height 3.6m each and depth of
foundation is 2.4 m. & total height of chosen building
including depth of foundation is 114 m. The static and
dynamic analysis has done on computer with the help of
STAAD-Pro software using the parameters for the design as
per the IS:1893-2002 Part-1 for the zones- 2 and 3. It was
concluded that not much difference in the values of Axial
Forces as obtained by static and dynamic analysis.
M. S. Aainawala et. al. (2014): Comparative study of
multi-storeyed R.C.C. Buildings with and without Shear
Walls:
He did the comparative study of multi-storeyed R.C.C.
Buildings with and without Shear Walls. They applied the
earthquake load to a building for G+12, G+25, G+38 located
in zone II, zone III, zone IV and zone V for different cases of
shear wall position. They calculated the lateral displacement
and story drift in all the cases. It was observed that Multi-
storeyed R.C.C. Buildings with shear wall is economical as
compared to without shear wall. As per analysis, it was
concluded that displacement at different level in multi-
storeyed building with shear wall is comparatively lesser as
compared to R.C.C. building without shear wall. Which is
important for building design and use of shear walls.
M. Mallikarjun et. al. (2016): on analysis and design of a
multi-storied residential building of ung-2+G+10:
Carried study on analysis and design of a multi-storied
residential building of ung-2+G+10 by using most