International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 07 Issue: 06 | June 2020 www.irjet.net p-ISSN: 2395-0072
© 2020, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 7618
GSM BASED SMART ENERGY METER
Prof Mr.Yogesh .B.Mandake
1
, Abhishek Pandey
2
, Mohit Sareen
3
, Pratyush Prasoon
4
, Rishav Raj
5
,
Ayush Agrawal
6
2,3,4,5,6
Student, Department of Electrical Engineering, Bharti Vidyapeeth (Deemed to be University) College of
Engineering, Pune, India
1
Assistant professor, Department of Electrical Engineering, Bharti Vidyapeeth (Deemed to be University) College of
Engineering, Pune, India
------------------------------------------------------------------------***-----------------------------------------------------------------------
Abstract— In this paper we are focusing on automatic
billing and metering, The integration of the GSM)Global
system for mobile communication) Short Message Service
(SMS) and Arduino provide the meter reading system with
some automatic functions that are predefined. The energy
consumption and electricity bill will be provided through
sms via GSM Module to the customer and to the concern
electricity department. An alert message will be send to the
customer and mahavitaran when the consumption unit
reading reaches beyond the specific threshold. This paper
gives details of hardware kit in which energy consumption
details in terms of power units and power units are going to
be displayed on the LCD(Liquid crystal display) and can be
notified to the customer via SMS and customer will also be
able to recharge with the help of GSM module as well as
ATMEGA328 microcontroller.
KEYWORDS: Arduino, LCD display, GSM modem,
Message receiver, Meter etc
I. INTRODUCTION
An Energy meter is a device that measures the entire
amount of electrical energy mostly consumed by areas like
commercial area, domestic. A smart energy meter (SEM) is
electrical device having energy meter chip for electric
energy consumed measurement and for digital
communication using wireless protocol and peripheral
devices for security purpose, data showing, meter
controlling etc [1]. It is clear that today’s emerging
developments in every sectors with growing demand of
electrical power, so electricity has become high priority for
every individual and also for organizations like a daily
needs. The very basic procedure of power supply includes
power generation, power transmission and power
distribution to the varied consumers and consumer could
also be corporate or domestic. Technically due to some
faults in the system, losses may occur. These losses are
often resolve or minimized using the advanced
technologies, but some losses unpredictable. These are the
losses caused by groups of people for their illegal access to
the facility distribution, which we said the facility theft [2].
In Proposed system, method of GSM (Global system for
mobile communication) based electronic energy meter is
used. This paper which can automatically sense the used
energy, and continuously records the reading, then sends it
for the billing to billing section through the GSM module.
Finally, after processing the collected data bill is generated
with web based system software
2. RELATED WORK
Mr. Paraskevakos was first introducer of Automatic Meter
Reading system, he used an advance technology developed
like wired or wireless such as, power lines, cable networks,
RF modules, GSM modules, LCD Display for just view
purpose. Mr. Jain Abhinandan etal.[3] developed an entire
Automated Energy Meter which has features like remote
monitoring and energy meter controlling. The
AMR(Automatic meter reading) continuously observe and
monitors the energy meter then sends meter reading to
the service provider via SMS(short message service). The
bill was allowed to pay online and option for payment by
credit card or debit card or even by net banking. Using a
GSM(Global system for mobile communication) , automatic
electric meter reading was built to demonstrate an
automatic electric meter reading during this network.
Meter reading may have many errors due to manual
system. The government employee who took meter
reading from the EB (Electronic board) he take
approximately quite 150 meters photo every day . Then
data of those photos will be get checked and put these data
at server. Reading taking person has to revisit that place