STUDY OF FAILURE AND DEFORMATION
CHARACTERISTICSOF SHEAR WALL WITH
OPENINGS USING CONCEALED STIFFENERS
Sanjivan Mahadik
Research Scholar, Department of Civil Engineering,
DBATU Lonere, India
S. R. Bhagat
Associate Professor and Head, Department of Civil Engineering,
DBATU Lonere, India
ABSTRACT
Shear wall is a structural member provided in multistoried structure for resisting
wind and seismic forces acting in the horizontal direction along the plane of the wall.
Openings are provided in shear wall generally for meeting a functional requirement
or for providing building services like ducts for electric wiring. Strength of any
structure reduces due to provision of opening and it is equally true for shear wall also.
Long walls fail generally by flexure whereas short wall fails by shear. In case of long
walls, failure is generally observed in the critical region which is at 1/6
th
height of the
wall on the either sides. However, short walls fail at the bottom due to the crushing of
concrete or yielding of reinforcement. Failure along diagonal is also observed in
some cases. If openings are provided in a shear wall, failure is observed at corners or
along edges of the shear wall. This type of failure is due to the stress concentration
around the opening. Strength of shear wall also decreases due to a reduction in
concrete area and discontinuity of reinforcement due to opening. Formation of cracks
in the early stage of loading leads to failure of shear walls. To avoid this problem of
early failure some provisions have to be made to improve the behavior of shear wall
with an opening. To overcome this problem it is proposed to providing concealed
diagonal stiffeners in shear wall along diagonal and periphery of opening. In the
present study, six shear wall models with the central opening are tested to know the
effect of concealed stiffeners in the shear wall with an opening. A significant
improvement was observed in the behaviour of the shear wall with opening using
concealed stiffeners. The main focus of this study is to know the deformation capacity,
crack pattern, failure mode and strain character.
Key words: Shear wall, stiffeners, openings, strength, and improvement.