Summary We report a series of 38 patients with intra-uterine devices with lost strings where hysteroscopic aid was required after routine retrieval procedures failed. Thirty-five intra-uterine devices could be removed easily with hysteroscope. In one patient a fragmented Lippes Loop was removed piecemeal hysteroscopically. Laparotomy was required in only one patient, for an extra-uterine Copper T. Hysteroscopy is thus a simple, safe and effective method for removing misplaced intra-uterine devices. Key words hysteroscopy, intra-uterine devices, lost strings Introduction With increased use of intra-uterine devices (IUDs) for contraception has come an increase in the number of related problems. 1 A frequent clinical problem is the loss of the filament at the external cervical os, the ‘lost tail’. The disappearance of the string or marker heralds potential problems such as retracted or torn off tail, misplacement within the cavity, intra-mural penetration or extra-uterine location. IUDs may be misplaced in as many as 5% of cases. 2 Procedures for retrieval of a misplaced device include extraction with a metal hook, artery forceps, cylindrical brush, 3 thread retriever 2 or dilatation and curettage. Success is not ensured with above methods; failure and uterine trauma may occur. Hysteroscopy as a diagnostic and operative technique has enabled safe retrieval of misplaced IUDs. This communication reports our experience with hysteroscopy for managing the so called ‘lost IUDs’. Method We present 38 cases with ‘lost IUDs’, referred to us after earlier repeated failed attempts at their removal. The age of the patients varied from 20-25 years with duration of use varying from 2.5-15 years. In all 38 cases the presence of an IUD was confirmed either by ultrasound or X-ray. A 7 mm operative hysteroscope with grasping forceps was used for extraction of the IUD. Paracervical block was used in all cases with additional intravenous sedation in four cases. Results The IUDs retrieved were Copper Ts in 32 cases, Lippes Loops in three cases, and a stainless steel ring in one case. The position and characteristics of the IUDs on hysteroscopy are shown in Table 1. In all 32 cases involving a Copper T the IUD was removed easily by grasping the vertical limb and withdrawing the hysteroscope. Lippes Loop was visualised in three cases, two of which were removed easily, whilst the third was fragmented and was removed piecemeal with the hysteroscope. In one patient with postmenopausal bleeding, although hysteroscopy revealed no IUD, an embedded Lippes Loop was found in the posterior uterine wall on hysterectomy. In another case laparotomy revealed a Copper T embedded in the omentum just behind the uterus. In this case no IUD was visible on hysteroscopy despite an X-ray reporting an intra-uterine IUD (Table 2). No immediate or late complication of hysteroscopy was encountered. Two women complained of pain and needed intravenous sedation in addition to the paracervical block. One postmenopausal woman and one apprehensive woman were given sedation before the start of the procedure. Mild pain was reported by six women. Four women described the procedure very uncomfortable, nine were mildly uncom- fortable and 15 described the procedure as comfortable. Discussion It is generally agreed that, once pregnancy has been excluded, proper investigations should be done to locate IUDs where threads are no longer visible. Appropriate methods are: sounding the uterine cavity with a probe; plain skiagram of abdomen and pelvis, AP and lateral view, with a probe or dilator in the uterus and ultrasonography. Blind manipulations with artery forceps, hooks and clamps for retrieval may be potentially dangerous, producing cervical or uterine injuries. 1 Valle and Freeman 1 advocated 229 The British Journal of Family Planning 2000: 26(4): 229-230 Hysteroscopic management of intra-uterine devices with lost strings Shubha Sagar Trivedi, MS, Professor; Madhu Goel, MD, Senior Resident ; Sandhi Jain, MS, Senior Resident, Department of Obstetrics and Gynaecology, Lady Hardinge Medical College and Associated Hospitals, New Delhi, India Correspondence: Dr SS Trivedi, Bungalow No. 22, Lady Hardinge Medical College, New Delhi-110001, India. Tel: 3360580, Email: drtrivedi@mantraonline.com (Accepted October 26 th , 1999) Key message point Hysteroscopy is a safe and effective method for locating intra-uterine devices with lost strings. Table 1 Position and characteristics of IUDs on hysteroscopy ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Hysteroscopic findings No. of Patients ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Cu T in normal position 26 Cu T lying transversely 2 Transverse limb of Cu T in anteroposterior diameter 2 Fibroid below Cu T 2 Lippes Loop in normal position 3 Ring IUD 1 IUD not visualised 2 ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Table 2 Removal of IUDs ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Removal Number of patients ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Easy Removal Cu T 31 Lippes Loop 3 Ring IUD 1 Fragmented Lippes loop 1 Hysterectomy (for postmenopausal bleeding) 1 Laparotomy (for extra-uterine Cu T) 1 ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– on September 2, 2021 by guest. Protected by copyright. http://jfprhc.bmj.com/ Br J Fam Plann: first published as 10.1783/147118900101194652 on 1 October 2000. Downloaded from