Research Article ISSN 2250-0480 Vol 2/Issue 1/Jan-Mar 2012 L-147 Life Science Pharmaceuticls analysis SPECTROFLUORIMETRIC DETERMINATION OF LEVOFLOXACIN IN PHARMACEUTICALS AND IN HUMAN URINE ARNALDO PEIXOTO DA SILVA 1 , ADERVAL SEVERINO LUNA 1* , THAIS MALCHER DA SILVA COSTA 1 , RICARDO QUEIROZ AUCELIO 2 , JEZ WILLIAN BATISTA BRAGA 3 , RICARD BOQUÉ 4 AND JOAN FERRÉ 4 1 Department of Analytical Chemistry, Rio de Janeiro State University, CEP 20550-013, Rio de Janeiro – RJ 2 Department of Chemistry, Pontifícia Universidade Católica do Rio de Janeiro, CEP 22453-900, Rio de Janeiro – RJ, Brazil 3 Department of Chemistry, Brasilia University, CEP 70910-900, Brasília – DF, Brazil 4 Department of Analytical Chemistry and Organic Chemistry, University Rovira i Virgili, Tarragona, Spain ABSTRACT Two spectrofluorimetric methods are proposed to determine levofloxacin in pharmaceutical tablets and spiked human urine. The first method allowed the determination of levofloxacin in aqueous solution using univariate (zero order) calibration. The analytical curve was linear to a concentration of levofloxacin of, at least, 300 ng mL -1 and the coefficient of correlation was 0.9988. The accuracy was evaluated using three different concentrations and the mean recovery was 97.6 ± 6.5% and the mean precision was lower than 2.0%, except for the concentration of 180 ng mL -1 for the analyst 2. The limit of detection (LOD) was 0.46 ng mL -1 , which can be considered adequate for this purpose. The method showed a good concordance when it was applied to Brazilian pharmaceutical formulation with a relative standard deviation of 3.5%. The second method used parallel factor analysis with standard additions for the determination of levofloxacin in urine. The scores, related to levofloxacin, were used to quantify levofloxacin in human urine, using linear regression and the standard additions method. The LOD was 1.4 ng mL -1 for urine sample diluted 1000 times with a mean precision of 3.0 ng. mL -1 and a root mean square error of calibration of 8.0 ng mL -1 . An additional application of this method was carried out to monitoring the levofloxacin in urine sample from a healthy man until of a complete excretion of this antibiotic with success. Key words : levofloxacin, human urine, second order standard addition method, PARAFAC. 1. INTRODUCTION Levofloxacin (LEVO), the levorotatory isomer of ofloxacin, exhibits activity against a broad spectrum of Gram-positive and Gram- negative bacteria. It is used to treat various infectious diseases such as community acquired and nosocomial pneumonia, skin structure infection, urinary tract infections or sepsis. 1 Several analytical techniques have been used for the determination of levofloxacin in different matrices, including adsorptive square- wave anodic stripping voltammetry, 2 flow injection analysis with absorption photometric, potentiometry and conductometry detection. 3 However, these methods do not present selective signals to discriminate a single analyte in mixtures