Correlative Imaging of Murine Pulmonary Valve Extracellular Matrix
Yifei Liu
1
, Yong-Ung Lee
2
, Binbin Deng
1
, Christopher K. Breuer
2
, David W. McComb
1
1
Center for Electron Microscopy and Analysis, The Ohio State University, Columbus, OH, United
States
2
Nationwide Children’s Hospital, Department of Tissue Engineering, Columbus, OH, United States
Heart valves have purely biomechanical structures that respond to the fluid dynamic environment caused
by heart palpitations. The pulmonary valve is responsible for unidirectional blood flow from the right
ventricle of the heart to the pulmonary arteries, leading to the respiratory system. Healthy pulmonary
valves consist of three leaflets, each compositionally and organizationally distinct [1]. Collagen is a
fibrillar extracellular matrix (ECM) protein is that responsible for the mechanical strength of heart valves.
Malformations and disorganization of collagen leads to biomechanical inefficiencies in the heart valve,
which manifest as physiological conditions such as stenosis or regurgitation [2]. In order to
comprehensively study the organization of the ECM, the physiological conditions of the valve must be
controlled and related to the microstructure of the ECM. We are developing a correlative workflow in
order to characterize the hierarchical organization of the collagen ECM and relate this to the
biomechanical properties of the valve.
Black 6 mice (C57BL/6) were anesthetized with a solution of ketamine and xylazine, and were sacrificed
according to IACUC approved protocols. An anastomosis was made between a pulmonary artery branch
and a polyethylene catheter (0.025” OD). A fixation solution of 2.5% glutaraldehyde, 2%
paraformaldehyde in 0.15 mM cacodylate buffer was flowed from the arterial side at a pressure of 20
mmHg. The pulmonary valves were excised and inspected under and optical microscope (Leica
Microsystems) to verify complete closure.
Specimens are stained with heavy metal atoms using a modified OTO procedure [3]. Tissues are stained
with: 1.5% potassium ferrocyanide (m/v) and 2% osmium textroxide, 1% thiocarbohydrazide, 2% osmium
textroxide (Electron Microscopy Sciences), 2% uranyl acetate, and lead aspartate. Between each change
of solution, tissues were washed with 0.15 mM cacodylate buffer or double distilled water (ddH2O).
Stained tissues dehydrated by ethanol treatments of 20% 50%, 70%, 90%, 100%, followed by 100%
acetone. Specimens were stepped through the graded mixtures of 25/75, 50/50, 75/25 and 100/0 (v/v)
Durcupan ACM resin (Electron Microscopy Sciences) in acetone. Embedded tissues were cured at 60°C
for 48 hours in Durcupan ACM resin.
Micro-computed tomography (μCT) was done using a Zeiss 520 Versa at the University of Manchester
X-Ray Imaging Facility. Serial block face scanning electron microscopy (SBF-SEM) was done using FEI
Teneo Volumescope in Eindhoven, Netherlands. Transmission electron microscopy (TEM) was
conducted at the Center for Electron Microscopy and Analysis with FEI CM-200T TEM.
Figure 1A is an optical image of a representative closed heart valve after being excised from the heart.
Figure 1B shows a μCT volume rendering of a pulmonary valve in an open configuration without an
applied transvalvular pressure. Using the μCT data, we can identify the position of the pulmonary valve
and cut a specimen block oriented along the arterial axis. Figure 1C shows the volume rendering obtained
from a series SBF-SEM images. A total of 100 slices were taken at a 20 nm slice thickness. At this
358
doi:10.1017/S1431927617002471
Microsc. Microanal. 23 (Suppl 1), 2017
© Microscopy Society of America 2017
https://doi.org/10.1017/S1431927617002471
Downloaded from https://www.cambridge.org/core. IP address: 3.235.178.143, on 14 Oct 2021 at 14:45:08, subject to the Cambridge Core terms of use, available at https://www.cambridge.org/core/terms.