Acoustic emission detection of fatigue damage in cruciform
welded joints
Jianguo Yu
a,
⁎, Paul Ziehl
a
, Fabio Matta
a
, Adrian Pollock
b
a
Department of Civil and Environmental Engineering, University of South Carolina, 300 Main Street, Columbia, SC 29208, United States
b
MISTRAS Group, Inc., 195 Clarksville Rd, Princeton Junction, NJ 08550, United States
abstract article info
Article history:
Received 7 October 2012
Accepted 28 March 2013
Available online 20 April 2013
Keywords:
Acoustic emission (AE)
Fatigue crack
Weldment
Cruciform joint
Structural health monitoring
Weld seams are critical points for the initiation of fatigue cracks in steel structures subjected to cyclic loads.
Semi-elliptical surface cracking at the toes of a fillet weld is not easily found when it is partially through the
thickness and subcritical. In this study the acoustic emission (AE) method is used to detect crack propagation
in cruciform fillet welded joints that are representative of typical fatigue sensitive details in steel bridge
superstructures. The effect of geometry and fatigue load on the AE data is investigated by varying the
width of the base plate and the stress ratio. AE data filtering based on load pattern, source location, and wave-
form feature analysis was implemented to minimize noise-induced AE signals and false indications due to
wave reflections. AE time domain features such as amplitude (b-value), counts, signal strength, and absolute
energy are employed to study the influence of geometry and fatigue load on the AE data.
© 2013 Elsevier Ltd. All rights reserved.
1. Introduction
Fatigue sensitive details in steel structures often include weldments
[1], where relatively high residual (“locked-in”) stresses, weld geome-
tries and discontinuities concur to the formation and growth of fatigue
cracks under cyclic loads [2]. The initiation of fatigue cracks is signifi-
cantly accelerated if initial defects exist in the weldments. A typical
example of fatigue sensitive detail in a steel bridge is shown in Fig. 1,
where a fatigue crack developed along a fillet weld at the gap between
the I-girder web and a welded stiffening plate. In fact, in a welded
I-girder superstructure the mechanical stress cycles produced by traffic
loads may cause the initiation and propagation of fatigue cracks in the
weld seam between the web or flange and stiffeners or diaphragm
connection plates. In the case of fatigue cracks at the weldment
between webs and diaphragm connection plates, the likelihood of
damage increases due to the combination of longitudinal bending
stresses (i.e., parallel to the longitudinal axis of the girder) and the
distortion effect from out-of-plane forces that are imparted by the dia-
phragm [2].
Representative cruciform specimens under uniaxial load that is
applied either on the main base plate or on symmetrically welded
plates are typically used to study these details, where fatigue cracks
may initiate at weld toes or at weld roots [3–5]. Fig. 2(a) shows
a cruciform specimen loaded along the main base plate, which simu-
lates either a portion of flange-to-stiffener connection or a web-
to-stiffener connection where secondary distortional effects are
neglected [4,5]. Under these conditions, weld root cracks propagate
through weld throats whereas weld toe cracks propagate into the
base plate forming semi-elliptical surface fatigue cracks [6]. Both
weld root cracks and weld toe cracks are likely to be non-visible as
they are partially through the thickness and subcritical, making tradi-
tional visual inspections ineffective [7]. The detection of fatigue cracks
in weldments is a significant challenge in the assessment of structural
integrity.
Acoustic emission (AE) monitoring has been utilized in welding
operations for the detection of weld defects during both the welding
and cooling phases [8,9], including special applications such as nuclear
reactor structures where high-quality weldments are required [10].
The cracks produced during welding and cooling make the weldments
susceptible to fatigue damage. Ultrasonic and radiographic (especially
X-ray) techniques are only available for post-weld inspection, whereas
the AE method can perform timely monitoring of the welding process
and offers the possibility to provide immediate feedback for the correc-
tion of anomalies [11]. Cold cracks may form after welding due to the
residual stresses produced by cooling of welded joints and the
heat-affected zone. It has been reported that cold cracking can generate
high-amplitude AE signals [8].
The sensitivity and non-invasive nature of AE method makes it
well suited for the health monitoring and assessment of civil steel
structures, such as bridges [12,13]. Studies on AE monitoring of
crack propagation in full size steel I-girders indicate that AE method
is able to detect small fatigue cracks at early stage of fatigue life of
the I-girders [7]. The effective use of AE method to detect active
Journal of Constructional Steel Research 86 (2013) 85–91
⁎ Corresponding author. Tel.: +1 803 777 8368; fax: +1 803 777 0670.
E-mail address: yu22@cec.sc.edu (J. Yu).
0143-974X/$ – see front matter © 2013 Elsevier Ltd. All rights reserved.
http://dx.doi.org/10.1016/j.jcsr.2013.03.017
Contents lists available at SciVerse ScienceDirect
Journal of Constructional Steel Research