J. Eng. Technol. Sci., Vol. 54, No. 1, 2022, 220101 Received March 17 th , 2022, Revised May 27 th , 2021, Accepted for publication June 4 th , 2021. Copyright ©2022 Published by ITB Institute for Research and Community Services, ISSN: 2337-5779, DOI: 10.5614/j.eng.technol.sci.2022.54.1.1 Assessing Log Reduction Values of Conventional Water Treatment Plants with Microbially Highly Polluted Raw Water Sources Arief Sudradjat 1,2,* , Made Sandhyana Angga 1,3 , Kevin Barlian 1 & Anindrya Nastiti 1,2 1 Research Center of Infrastructure and Regional Development, Institut Teknologi Bandung, Jalan Ganesa No. 10, Bandung 40132, Indonesia 2 Faculty of Civil and Environmental Engineering, Institut Teknologi Bandung, Jalan Ganesa No. 10, Bandung 40132, Indonesia 3 Faculty of Engineering, Udayana University, Jalan Kampus Bukit Jimbaran, Kuta Selatan, Badung 80361, Bali, Indonesia *E-mail: ariefs@tl.itb.ac.id Highlights: Microbially highly polluted drinking water sources were characterized for pathogens. The log reduction value of a conventional water treatment plant was assessed for bacteria and protozoa drinking water safety. The log reduction values of the pre-sedimentation and combined flocculation- sedimentation units in conventional water treatment plants need to be (re)assessed. Abstract. Because of the global outlook of microbial pathogens contributed by river basins that are characterized by highly populated urbanized areas and other activities with poor wastewater management, it is imperative to assess the sufficiency of conventional water treatment plants with microbially highly polluted raw surface water sources in supplying pathogen-free drinking water. By using the log reduction value (LRV), the microbial safety of the drinking water supply from WTP Badaksinga, Bandung City, Indonesia, was assessed, from the raw water sources to the conventional water treatment units. E. coli, total coliform, and Clostridium perfringens (as a surrogate of the Cryptosporidium parvum protozoan) were selected as pathogens. It was found that with E. coli concentrations of > 20,000 MPN/100 ml, all the raw water sources should be categorized as not suitable for drinking water sources. The LRVs of conventional treatment units ranged from 0.67 to 1.4 for all pathogens. For the disinfection unit, the LRVs ranged from 3.0 to 3.71 for E. coli and total coliform, and 0 for Clostridium perfringens. Based on the results, the drinking water from WTP Badaksinga is safe from bacteria contamination but theoretically requires an additional barrier for protozoa safety. The assessment found that the LRVs of pre- sedimentation and combined flocculation-sedimentation units in conventional treatment systems need to be (re)assessed. Keywords: conventional treatment; drinking water; LRV; microbial safety; raw water source.